FULLY MICROPROCESSOR BASED SYSTEM WITH FEATHER TOUCH PANEL

1. IMAGE INTENSIFIER:
Thomson / Toshiba 6" / 9" Imaging System with High Performance Capability

2. CONTROL AND GENERATOR:

  • All Operation on Control Panel Keyboard
  • Microprocessor based control with Feather Touch Panel
  • Generator Surgipicks - IIC unit delivers excellent radiography
  • Radiographic output upto 100 mA
  • Fluoroscopy 0-5 mA (as per kvp selection) variable in steps of 0.1 mA
  • kvp variation fom minimum 40 kvp to 100 kvp in steps of 1 kvp
  • 3 Operation Modes Normal, Pulsed and ABS

CONTROL FEATURES:

FULLY MICROPROCESSOR BASED

  • Digital kvp meter display
  • Digital mA meter display
  • Digital radio timer display
  • Foot-Switch for spot operation
  • Feather Touch Keyboard with appropriate LED indications

VERSATILITY THROUGH USER FRIENDLY DESIGN

X-RAY TUBE-HEAD

  • Dual Focii having 0.6 mm and 1.8 mm Focus
  • Anode heat storage capacity 30 KJ
  • Anode cooling rate 250 W/hr


VERSATILITY THROUGH USER FRIENDLY DESIGN

X-RAY TUBE-HEAD

  • Dual Focii having 0.6 mm and 1.8 mm Focus
  • Anode heat storage capacity 30 KJ
  • Anode cooling rate 250 W/hr



"C-ARM" FEATURE




Rotation 360°
Source to I.I. Distance 90 cms
Arc Orbital Movements 110°
Panning 25°
Horizontal Travel 23 cms
Vertical Motorised Movement 38 cms
Detachable Cassette Holder 10" x 12" or 8" x 10" film


TV - MONITOR

  • 15" /17" Color
  • 625 Lines I Frame
  • 50 Hz
  • 230VAle with high-resolution display capability 2 numbers monitor supplied.
  • Image rotation in desired direction I position offered as standard

OPTION (1)

IMAGE MEMORY - DIP (Digital Image Processing Memory)

  • Acquision is upto 25 frames /sec. (Selectable in increment of one)
  • 50 Cineloops (1 cineloops = 200 images)
  • Total Storages 25,000 images + 405 Cineloops or 1, 05,000 images for permanent storage
  • Storage of Cineloops with frame by frame viewing and images, Auto run of Cineloops
  • Patient information database to store, manage, retrieve patient
  • Thumbnail viewing of images
  • Post image processing like rotation, zooming, panning, measurements, annotations and edge sharpening
  • CD Writing and printing upgrade to DSA and DSI Systems


OPTION (2)

IMAGE MEMORY - (Hardware Memory with PC Interface)

  • 15" / 17" B/W Monitor
  • 32 Frame Memory with Dual Video Output and Frame
  • Step-Wise Image Integration (2/4/8/16)
  • Image Reversal - Positive I Negative
  • Pulsed Fluoroscopy
  • Image Resolution (512 x 512) Pixels
  • Dyamic Storage of Image
  • Digital Display for Image Selection
  • Zoom and Pan of Image possible



MODEL HF-64 HF-94 R ECONOMY
Type of Generator 40 kHz, High Frequency 40 kHz, High Frequency Full Wave Rectified
Tube Type Double Focus Stationary Anode Double Focus Rotating Anode Double Focus Stationary Anode
X-Ray Tube Fluoro 0.6 mm x 0.6 mm Fluoro 0.3 mm x 0.3 mm Fluoro 0.6 mm x 0.6 mm
Focal Spot Radio 1.5 mm x 1.5 mm Radio 0.6 mm x 0.6 mm Radio 1.8 mm x 1.8 mm
Fluro/Radio kVp 40 - 110 kVp 40 - 120 kVp 40 - 100 kVp
Fluoroscopic mA 0.1 - 3.0 mA 0.1 - 4.0 mA 0.1 - 3.0 mA
Fluoroscopic Timer 5 Min 5 Min 5 Min
Radiographic mAs upto 220 mAs upto 220 mAs upto 200 mAs
Power Requirement 220V/50 Hz 3.5 KW 220V/50 Hz 5.0 KW 220V/50 Hz 2.4 KW
Image Intensifier 6" (150mm) 9" (230mm) 6" (150mm)