1. IMAGE INTENSIFIER:
Thomson / Toshiba 6" / 9" Imaging System with High Performance Capability
2. CONTROL AND GENERATOR:
- All Operation on Control Panel Keyboard
- Microprocessor based control with Feather Touch Panel
- Generator Surgipicks - IIC unit delivers excellent radiography
- Radiographic output upto 100 mA
- Fluoroscopy 0-5 mA (as per kvp selection) variable in steps of 0.1 mA
- kvp variation fom minimum 40 kvp to 100 kvp in steps of 1 kvp
- 3 Operation Modes Normal, Pulsed and ABS
|
|
CONTROL FEATURES:
FULLY MICROPROCESSOR BASED
- Digital kvp meter display
- Digital mA meter display
- Digital radio timer display
- Foot-Switch for spot operation
- Feather Touch Keyboard with appropriate LED indications
|
 |
VERSATILITY THROUGH USER FRIENDLY DESIGN
X-RAY TUBE-HEAD
- Dual Focii having 0.6 mm and 1.8 mm Focus
- Anode heat storage capacity 30 KJ
- Anode cooling rate 250 W/hr
|

|
VERSATILITY THROUGH USER FRIENDLY DESIGN
X-RAY TUBE-HEAD
- Dual Focii having 0.6 mm and 1.8 mm Focus
- Anode heat storage capacity 30 KJ
- Anode cooling rate 250 W/hr
|

|
"C-ARM" FEATURE
| Rotation |
360° |
| Source to I.I. Distance |
90 cms |
| Arc Orbital Movements |
110° |
| Panning |
25° |
| Horizontal Travel |
23 cms |
| Vertical Motorised Movement |
38 cms |
| Detachable Cassette Holder |
10" x 12" or 8" x 10" film |
|
|

|
TV - MONITOR
- 15" /17" Color
- 625 Lines I Frame
- 50 Hz
- 230VAle with high-resolution display capability 2 numbers monitor supplied.
- Image rotation in desired direction I position offered as standard
OPTION (1)
IMAGE MEMORY - DIP (Digital Image Processing Memory)
- Acquision is upto 25 frames /sec. (Selectable in increment of one)
- 50 Cineloops (1 cineloops = 200 images)
- Total Storages 25,000 images + 405 Cineloops or 1, 05,000 images for permanent storage
- Storage of Cineloops with frame by frame viewing and images, Auto run of Cineloops
- Patient information database to store, manage, retrieve patient
- Thumbnail viewing of images
- Post image processing like rotation, zooming, panning, measurements, annotations and edge sharpening
- CD Writing and printing upgrade to DSA and DSI Systems
|

|
OPTION (2)
IMAGE MEMORY - (Hardware Memory with PC Interface)
- 15" / 17" B/W Monitor
- 32 Frame Memory with Dual Video Output and Frame
- Step-Wise Image Integration (2/4/8/16)
- Image Reversal - Positive I Negative
- Pulsed Fluoroscopy
- Image Resolution (512 x 512) Pixels
- Dyamic Storage of Image
- Digital Display for Image Selection
- Zoom and Pan of Image possible

| MODEL |
HF-64 |
HF-94 R |
ECONOMY |
| Type of Generator |
40 kHz, High Frequency |
40 kHz, High Frequency |
Full Wave Rectified |
| Tube Type |
Double Focus Stationary Anode |
Double Focus Rotating Anode |
Double Focus Stationary Anode |
| X-Ray Tube |
Fluoro 0.6 mm x 0.6 mm |
Fluoro 0.3 mm x 0.3 mm |
Fluoro 0.6 mm x 0.6 mm |
| Focal Spot |
Radio 1.5 mm x 1.5 mm |
Radio 0.6 mm x 0.6 mm |
Radio 1.8 mm x 1.8 mm |
| Fluro/Radio kVp |
40 - 110 kVp |
40 - 120 kVp |
40 - 100 kVp |
| Fluoroscopic mA |
0.1 - 3.0 mA |
0.1 - 4.0 mA |
0.1 - 3.0 mA |
| Fluoroscopic Timer |
5 Min |
5 Min |
5 Min |
| Radiographic mAs |
upto 220 mAs |
upto 220 mAs |
upto 200 mAs |
| Power Requirement |
220V/50 Hz 3.5 KW |
220V/50 Hz 5.0 KW |
220V/50 Hz 2.4 KW |
| Image Intensifier |
6" (150mm) |
9" (230mm) |
6" (150mm) |
|
|
|
|
|