Home About Us Contact
 


An
ISO 9001:2000
ISO 13485:2003
Certified Company

BIS & AERB Approved

 
300mA & 500 mA
 
PICKS 3010 D, 300mA, 100/125Kv DIAGNOSTIC X-RAY GENERATOR.
 
Picks 3010 D X-Ray generator is highly suitable for all radiography, fluoroscopy, spot filming, image intensifier with TV system and other special examinations with manual and motorised Bucky Tables.
 
SALIENT FEATURES

  • Two pulse single phase X-ray generator with maximum rating 300mA and 100/125Kv (24Kw)
  • Full wave rectifications.
  • Shorter exposure time 10ms.
  • Digital display of mA, Kv, & mAs.
  • Automatic computation of mAs digitally.
  • Kv display shows F-Kv ON spot mode & R-Kv-Off spot mode.
  • Overload protection to block the exposure and R-O-L & F-O-L glow.
  • Rapid rotor anode braking circuit (to increase tube life).
  • Continuous fluoroscopy by pressing F-RST push button.
  • Double mA range compact meter with double lamp.
  • LED lamps to indicate focii (different focus of the tube).
  • Spot film on any technic is possible.
  • High voltage silicon rectifier for low losses and consistent radiographic results.
TECHNICAL DATA

Power Supply Nominal 415 V at 0.5Ω power line resistance 50/60 Hz.
Output 300mA and 100/125Kvp [24Kw as per IS 7620-1986]
Fluoroscopy 40Kv to 100Kv in 8 steps
Radiography

40Kv to 115Kv in 8 steps.
0Kv to 10Kv in 6 steps.
On small focus 50, 100, 150mA.
On large focus 100, 200, 150mA.

Timer 10ms to 5s in 23 steps.
X-Ray Tube Single Tube/Double Tube Compatible with BELDRA-1-125/20/40/Equivalent imported tubes with higher rating.
 
PICKS 5012 D, 500mA, 125Kv DIAGNIOSTIC X-RAY GENERATOR
 
Picks 5012 D X-Ray generator is highly suitable for all radiography, fluoroscopy, spot filming, image intensifier with TV system and other special examinations with manual and motorised Bucky Tables.
 
SALIENT FEATURES

  • Two pulse single phase X-ray generator with maximum rating 500mA and 125Kv (40Kw).
  • Full wave rectifications.
  • Shorter exposure time 10ms.
  • Digital display of mA, Kv, & mAs.
  • Automatic computation of mAs digitally.
  • Kv display shows F-Kv ON spot mode & R-Kv-Off spot mode.
  • Overload protection to block the exposure and R-O-L & F-O-L glow.
  • Rapid rotor anode braking circuit (to increase tube life).
  • Continuous fluoroscopy by pressing F-RST push button.
  • Double mA range compact meter with double lamp.
  • LED lamps to indicate focii (different focus of the tube).
  • Solid state X-ray contacting system in lieu of elctro-magnetic contacting system.
  • Spot film on any technic is possible.
  • High voltage silicon rectifier for low losses and consistent radiographic results.

TECHNICAL DATA
Power Supply Nominal 415 V at 0.3Ω power line resistance 50/60 Hz.
Output 500mA and 125/125Kvp [40Kw as per IS 7620-1986]
Fluoroscopy 40Kv to 100Kv in 8 steps
Radiography

40Kv to 115Kv in 8 steps.
0Kv to 10Kv in 6 steps.
On small focus 50, 100, 150mA.
On large focus 100, 200, 300,500mA.

Timer 10ms to 5s in 23 steps.
X-Ray Tube Single Tube/Double Tube Compatible with BEL DRA-1-125/20/40/Equivalent imported tubes with higher rating.
X-Ray with motorised table
Retrofit

 

Copyright 2004 PICKS MEDICAL SYSTEMS LTD. Design & Managed by Matrix Consulting Services